Dissolvable / Soluble Mag Magnesium Alloy Billets Frac Balls Bridge Plug Customized Dissolvable Magnesium Alloy The Dissolvable Frac Plug
Product Details:
| Place of Origin: | Hunan China |
| Brand Name: | High Broad |
| Certification: | ISO / ASTM / GB |
| Model Number: | MG Dissolve / Soluble |
Payment & Shipping Terms:
| Minimum Order Quantity: | 100 kgs |
|---|---|
| Price: | according to quantity |
| Packaging Details: | In wooden pallet |
| Delivery Time: | 14 days |
| Payment Terms: | T/T |
| Supply Ability: | 500 mt/month |
|
Detail Information |
|||
| Grade: | Dissolving , Soluble Magnesium | Elongation: | 8% Or Customized |
|---|---|---|---|
| Alloy: | Magnesium | Use: | Downhole Tools In Oil / Gas Field |
| Produce Way: | Cast & Machined | Other: | Dissolve Magnesium Alloy |
| Thermal Conductivity: | 156 W/mK | Heat Treat: | T5 Or Customized |
| Highlight: | Soluble Magnesium Alloy Billets,Magnesium Alloy Billets Frac Balls,Magnesium Alloy Billets Bridge Plug |
||
Product Description
Dissolving hydraulic fracturing ball for fracturing operation
MD quickly dissolving Magnesium alloy for oil well drilling
Degradable Magnesium Billet dissolving soluble magnesiumalloy billet for oil extraction industry
Dissolving Magnesium Alloys for Downhole application
Magnesium alloy designed for down-hole oil and gas fracking tools dissolves after use
a proprietary high-strength, soluble magnesium alloy developed specifically for making down-hole oil and gas industry fracking tools that quickly and safely dissolve after use
![]()
Dissolvable Frac Ball HCL Acid Resistance Test
Experimental purpose: Obtain the acid corrosion resistance of the coating soluble ball in a certain temperature and certain concentration of HCL solution through experimental observation
Experimental steps:
1. Prepare experimental equipment, soluble ball, solute (HCL), clean water, beaker, balance, vernier caliper Constant temperature water bath
2. Check the appearance and size of the soluble ball, and take a photo
3. Prepare 20% HCL solution
4. Immerse the coating soluble ball in HCL solution
5. The constant temperature box maintains the HCL solution at a certain temperature, and observes the acid corrosion resistance of the soluble ball
6. Take out the soluble ball at intervals, check the appearance, shape and size of the soluble ball, and record the soluble ball weight, reconstitute the acid solution, continue to observe the corrosion resistance of the soluble ball
Test index: record the corrosion resistance of the soluble ball every 24 hours
Experimental considerations: every time during an acid resistance check, pay attention to safety, record relevant data and take pictures clearly